ROTARY DAMPERS
FEATURES
➢ Damping direction: CW / CCW
➢ TD112 series dampers are stronger version than TD56 series dampers on durability-wise.
➢ TD112 series dampers have 2 types of shaft-length.
➢ RoHS compliance
TORQUE VALUE
0.45 - 2.94 N・m
The above drawing shows operation angle of TD112A1/A2 series dampers. Operation angle of TD112B1/B2 series is symmetrical to the vertical line. Shaft position at the time of shipment is closed position.
TEST CONDITION
①Setting-up time: 20 sec/cycle
②Load torque:
- 1.0 N・m (10kgf・cm)
- 1.5 N・m (15kgf・cm)
- 2.0 N・m (20kgf・cm)
- 2.5 N・m (25kgf・cm)
- 3.0 N・m (30kgf・cm)
③Temperature: 23℃±2℃
④Angle for measuring the closing time: 70° → 0°
⑤Radial force: nothing
⑥Closing time after durability test: 1 sec or more
After the damper is stabilized at room temperature for 1 hour or more, the closing time is measured using TOK in-house device.