ROTARY DAMPERS

Rotary damper - TD27 / TD28 and Bracket

  • image

     TD27 Series

  • image

     TD28 Series

  • image

     TD27/28 Bracket


Torque adjustable device

  • image


  • image



Damping hinges

  • image


  • image

     * Case2 / Damper shaft delivery position needs to be changed from closed position to open position

image

Mounting hinge mounting dimensions


FEATURES
Damping direction: CW / CCW
TD27/28 series dampers have the torque adjustable device.
By combining with exclusive brackets, TD27/28 series can be used as hinges.
RoHS compliance

TORQUE VALUE
0.49 - 1.96 N・m

Rotary damper dimensions

  • image

  • image

  • image

    The above drawing shows operation angle of TD27A1 (CW) series dampers. Operation angle for TD27B1 (CCW) series dampers are symmetrical to the vertical line. Shaft position at the time of shipment is closed position.

  • image

    The above drawing shows operation angle of TD28A1 (CW) series dampers. Operation angle for TD28B1 (CCW) series dampers are symmetrical to the vertical line. Shaft position at the time of shipment is closed position.

  • image

  • image


Bracket and cap dimensions

image

DURABILITY

Each damper is set-up with an applied torque and weight on the shaft of the testing device. Measurements for closing time are taken under above condition.
  • image

  • image

    TEST CONDITION
    ①Setting-up time: 15 sec/cycle
    ②Load torque:
    - 1.27 N・m (13kgf・cm)
    - 1.96 N・m (20kgf・cm)
    ③Temperature: 23℃±2℃
    ④Angle for measuring the closing time: 70° → 0°
    ⑤Radial force: nothing
    ⑥Closing time after durability test: 1.5 sec or more

TEMPERATURE CHARACTERISTICS

image